Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 3649, 2024 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-38351306

RESUMEN

The six-minute step test (6MST) has been shown to be effective in assessing exercise capacity in individuals with COPD regardless of severity and, despite its easy execution, accessibility and validity, information on the prognostic power of this test remains uncertain. The aim of this study is to investigate whether the 6MST can predict the occurrence of exacerbations in patients with COPD. This is a prospective cohort study with a 36-month follow-up in patients with COPD. All patients completed a clinical assessment, followed by pulmonary function testing and a 6MST. The 6MST was performed on a 20 cm high step; heart rate, blood pressure, oxygen saturation, BORG dyspnea and fatigue were collected. Sixty-four patients were included in the study, the majority being elderly men. Performance on the 6MST demonstrated lower performance compared to normative values proposed in the literature, indicating a reduced functional capacity. Kaplan Meier analysis revealed that ≤ 59 steps climbed during the 6MST was a strong predictor of COPD exacerbation over a 36-month follow-up. We have identified a minimal threshold number of steps (≤ 59) obtained through the 6MST may be able predict the risk of exacerbations in patients with COPD.


Asunto(s)
Prueba de Esfuerzo , Enfermedad Pulmonar Obstructiva Crónica , Masculino , Humanos , Anciano , Estudios de Seguimiento , Estudios Prospectivos , Pruebas de Función Respiratoria , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico
2.
Heart Lung ; 62: 64-71, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37327614

RESUMEN

BACKGROUND: Individuals with COPD have an imbalance of cardiac autonomic control. In this context, HRV is considered an important tool for assessing cardiac sympathetic and parasympathetic balance, however it is a dependent evaluator measure and subject to methodological biases that may compromise the interpretation of results. OBJECTIVE: This study examines the inter- and intrarater reliability of HRV parameters derived from short-term recordings in individuals with COPD. METHODOLOGY: Fifty-one individuals of both genders with COPD clinical diagnosis confirmed by the pulmonary function test and aged ≥50 years were included. The RR interval (RRi) were recorded during a 10 min period on supine position using a portable heart rate monitor (Polar® H10 model). The data were transferred into Kubios® HRV Standard analysis software and analyzed within the stable sessions containing 256 sequential RRi. RESULTS: The intraclass correlation coefficient (ICC) ranged from 0.942 to 1.000 according to the intrarater analysis by Researcher 01 and 0.915 to 0.998 to the intrarater by Researcher 02. The interrater ICC ranged from 0.921 to 0.998. The coefficient of variation was up to 8.28 for Researcher 01 intrarater analysis, 9.06 for Researcher 02 intrarater analysis and 13.07 for interrater analysis. CONCLUSION: The measurement of HRV using a portable heart rate device in individuals with COPD present acceptable values of intra- and interrater reliability, supporting the use of HRV in the clinical and scientific scenario. Furthermore, it is important that the data analysis be performed by the same experienced evaluator.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Masculino , Femenino , Frecuencia Cardíaca/fisiología , Reproducibilidad de los Resultados , Corazón , Sistema Nervioso Autónomo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...